{"id":116,"date":"2018-02-20T19:09:45","date_gmt":"2018-02-20T19:09:45","guid":{"rendered":"\/?p=116"},"modified":"2018-06-06T19:33:36","modified_gmt":"2018-06-06T19:33:36","slug":"neptune-pulsmate-electronic-register","status":"publish","type":"post","link":"https:\/\/redsealmeasurement.mojoe.net\/es\/neptune-pulsmate-electronic-register\/","title":{"rendered":"Neptune Pulsmate Electronic Register"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-197 size-full\" src=\"\/wp-content\/uploads\/2017\/11\/neptune-pulsemate.jpg\" alt=\"\" width=\"216\" height=\"216\" srcset=\"https:\/\/redsealmeasurement.mojoe.net\/wp-content\/uploads\/2017\/11\/neptune-pulsemate.jpg 216w, https:\/\/redsealmeasurement.mojoe.net\/wp-content\/uploads\/2017\/11\/neptune-pulsemate-150x150.jpg 150w\" sizes=\"(max-width: 216px) 100vw, 216px\" \/>The Neptune Pulsmate Electronic Register enhances the flow management capabilities of Type MP and magnetic drive Type S flowmeters. This battery or externally powered register displays rate and total simultaneously and includes a scalable pulse output for interfacing with supervisory control.<\/p>\n<p><strong>The Pulsmate Electronic Register can be used with the Neptune Magnetic Type S and Type MP Meters. <\/strong><\/p>\n<h3>Applications include<\/h3>\n<ul>\n<li>The Pulsmate allows a battery power facility field mounting to replace a mechanical system where no local power is available.<\/li>\n<li>Localized resettable totalizer is ideal for simple manual batching.<\/li>\n<li>Local indication of flow rate from a Neptune PD meter on the Pulsmate allows simple process monitoring.<\/li>\n<li>Monitor long term cumulative flow through a meter for allocation or inventory management purposes.<\/li>\n<li>Use the pulse output to a flow computer to control batching and blending operations.<\/li>\n<li>Optional 4-20 mA analog output provides remote flowrate indication to a centralized process control system.<\/li>\n<li>Alarm feature signals if flow rate drifts outside the preset hi-low limits making the Pulsmate very useful in cooling water monitoring applications and quality control applications.<\/li>\n<\/ul>\n<h3>Features<\/h3>\n<ul>\n<li>Electronic calibration provides faster set-up and eliminates the need to replace change gears.<\/li>\n<li>Simultaneous rate and total displays<\/li>\n<li>Track both flow rate and cumulative volume<\/li>\n<li>Optional alarms signal when flow rate is not within upper or lower set point limits<\/li>\n<li>Selectable totalizer models<\/li>\n<li>Resettable for measuring repetitive processes<\/li>\n<li>Non-Resettable (cumulative) for tracking flow over extended time<\/li>\n<li>Scalable pulse output enables remote totalization and process monitoring anytime, anywhere<\/li>\n<li>Track both flow rate and cumulative volume<\/li>\n<li>Optional alarms signal when flow rate is not within upper or lower set point limits<\/li>\n<li>Retrofittable to existing flowmeters \u2013 compatible with Type MP and magnetic drive Type S flowmeters<\/li>\n<li>No mechanical gear trains<\/li>\n<li>Durable housing made out of Isoplast enclosure<\/li>\n<\/ul>\n<h3>Literature<\/h3>\n<p><a href=\"\/literature\/M-302(C).pdf\" target=\"_blank\" rel=\"noopener\">O&amp;M Manual<\/a> \u2192<br \/>\n<a href=\"\/literature\/TS-302(F).pdf\" target=\"_blank\" rel=\"noopener\">Tech Sheet<\/a> \u2192<\/p>","protected":false},"excerpt":{"rendered":"<p>The Neptune Pulsmate Electronic Register enhances the flow management capabilities of Type MP and magnetic drive Type S flowmeters.<\/p>","protected":false},"author":1,"featured_media":197,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[],"_links":{"self":[{"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/posts\/116"}],"collection":[{"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/comments?post=116"}],"version-history":[{"count":0,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/posts\/116\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/media\/197"}],"wp:attachment":[{"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/media?parent=116"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/categories?post=116"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/redsealmeasurement.mojoe.net\/es\/wp-json\/wp\/v2\/tags?post=116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}